DigiDesign ADAT Bridge I/O User's Guide Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
ADAT Bridge I/O48
10 In the Pro Tools Session Setup window,
choose the sample rate that matches the
material on the ADAT(s).
11 In the Pro Tools Session Setup window,
check and enable the MTC to Port button,
then select the Digital TimePiece’s OMS
port in the pop-up that appears below this
button.
12 In the Pro Tools Session Setup window,
choose the SMPTE frame rate that matches
the rate chosen on the Digital TimePiece.
13 Create the number of destination audio
tracks you wish to transfer from the
ADAT(s). Make sure the destination tracks
each have a different voice assignment in
the Pro Tools session.
14 Use the Input Selector of each destina-
tion track to assign its input. Inputs 1-8
correspond to the ADAT Bridge I/O’s Group
A inputs. Inputs 9-16 correspond to ADAT
Bridge I/O’s Group B inputs. If you have ad-
ditional ADAT Bridges/ADATs, assign their
inputs as well. (When Ch 1-2 input set to
ADAT, Pro Tools automatically sets I/O
pop-ups to ADAT Bridge Group A/B input
& output labels.)
15 Select a Pro Tools monitoring mode
(Auto Input Monitor or Input Only Moni-
tor). Use Input Only Monitor if you wish to
be able to hear incoming material on
record-enabled Pro Tools tracks before you
initiate recording. Use Auto Input Monitor
to hear incoming material only during ac-
tual recording.
16 Choose Time Code from the Pro Tools
Display menu so that the Pro Tools counter
will display time in SMPTE frames.
17 Choose the desired Pro Tools online re-
cording mode: Record Online at Time Code
Lock, or Record Online at Insertion/Selec-
tion. To do this, choose Preferences from
the Pro Tools Setups menu. Click the Oper-
ation button and enable the desired mode
at the bottom of this dialog. If you are not
familiar with these modes, refer the expla-
nation in your Pro Tools Reference Guide.
18 Set the Pro Tools pre-roll time to at least
10 seconds.
19 Click the Pro Tools Record button
20 Click the Pro Tools Play button.
21 When you have finished recording,
click Pro Tool’s Stop button. The ADAT will
stop recording.
Recording Tracks from Pro Tools to
ADAT with a Digital TimePiece
This setup explains how to perform a syn-
chronized Pro Tools-to-ADAT track transfer
using the Digital TimePiece.
To transfer audio from Pro Tools to ADAT:
1 Make sure your DTP is configured as de-
scribed in the previous ADAT-to-Pro Tools
setup.
2 Make sure that the ADAT tape is format-
ted to the same sample rate as the Pro Tools
material you intend to transfer.
3 On the ADAT, record-enable the destina-
tion ADAT tracks. Make sure that the same
tracks are not configured as Pro Tools input
sources or a feedback loop will occur.
4 In Pro Tools, open the session with the
audio you wish to transfer to the ADAT.
5 In the Pro Tools Session Setup window,
set Channel 1-2 input to ADAT.
6 In the Pro Tools Session Setup window,
set the Pro Tools Sync Mode to Internal.
Page view 51